Technical Specifications of NSN
Overall Length:
7.500 inches
Overall Height:
2.625 inches
Overall Width:
9.750 inches
Body Length:
6.750 inches
Unthreaded Mounting Hole Diameter:
0.218 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
7.000 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.625 inches
Operating Tempurature Range:
+0.0/+85.0 degrees celsius
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
Operating Current Rating Per Function In Amps:
5.0 1st radio interference
Operating Current Rating Per Function In Amps:
5.0 2nd radio interference
Operating Current Rating Per Function In Amps:
5.0 3rd radio interference
Maximum Voltage Drop Per Function:
2.0 volts ac 1st radio interference
Maximum Voltage Drop Per Function:
2.0 volts ac 2nd radio interference
Maximum Voltage Drop Per Function:
2.0 volts ac 3rd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
Mounting Facility Screw Thread Series Designator:
Unf
Inclosure Type:
Hermetically sealed
Mounting Facility Type And Quantity:
6 threaded stud
Mounting Facility Type And Quantity:
6 unthreaded hole
Functional Terminal Type And Quantity:
3 threaded stud output 2nd function
Functional Terminal Type And Quantity:
3 threaded stud input 1st function
Operating Voltage Rating And Type Per Function:
130.0 volts ac 2nd radio interference 2nd function and 400.0 volts dc 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
130.0 volts ac 1st radio interference 1st function and 400.0 volts dc 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
130.0 volts ac 3rd radio interference 3rd function and 400.0 volts dc 3rd radio interference 3rd function
Thread Size:
0.190 inches
Maximum Dielectric Withstanding Dc Voltage:
800.0 volts at sea level
Style Designator:
Rectangular terminal/terminals on opposite surfaces
Item Name:
Electrical Noise Filter
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC